Furnace Vent Pipe Clearance Height Above Roof
The 1992 vent sizing tables require that all type b gas vents terminate above the roof with a listed cap or listed roof assembly in accordance with the manufacturer s instructions.
Furnace vent pipe clearance height above roof. Vent caps 12 and smaller may terminate a distance above the roof if 8 feet or more away from a vertical surface as follows. If the pipe is farther than 10 feet from the roof. The top of a chimney pipe must extend at least 2 feet above the peak of the roof if the pipe is within 10 feet of the peak. Also known as the type b this vent is operating on the natural air convection.
If the previous calculation results in the required height of 64 inches we can see that the top of the pipe will not rise above the roof peak but would still meet the requirements of the rule. An exception is made for non combustible walls such as solid masonry or concrete. While one foot above the roof surface may meet the recommendations for fire clearances in one storey buildings or in buildings with heating equipment on the uppermost floor the total chimney height may be inadquate to establish sufficient and safe draft unless you extend the chimney. Above the roof plumbing vent height.
Notes to the table above 1 measure on the up roof or shorter height side of the chimney 2 watch out. For gas vents or a type l vent this distance above the roof surface must be at least 2 ft 0 61m. For gas fired water heater vents. Table of type b vent rooftop clearance requirements.
Table illustrations of the required space between a direct or side wall vent for a gas fired heating appliance and building windows doors corners gas meter air intakes sidewalks balconies. Vertical blue line along the left side of the chimney in our photo. Upc i 906 1 and 906 2. 6 minimum clearance from single wall vent pipe or flue vent connector to any combustible material.
When the vent is withdrawing air from the house it expels the gas outside through the vent. For 18 feet of run you would have a rise of 72 inches. For the next example you have a shorter chimney height. Gas appliance direct vent clearances distances from direct gas vent to building features sidewall vent direct vent direct exhaust systems for gas fired heaters water heaters other appliances.
This specification makes sure steep roof slopes are cleared. The top of the chimney should be at least 3 ft 0 92 m above the roof surface.